SG-IO-IOL-16DI Industrial IO-Link Hub Module
video
SG-IO-IOL-16DI Industrial IO-Link Hub Module

SG-IO-IOL-16DI Industrial IO-Link Hub Module

🔌 16-Channel High-Density Input:Connect up to 16 sensors in a single module. This significantly reduces control cabinet wiring and saves valuable installation space.
🛡️ IP67 Industrial-Grade Protection:Features a fully sealed housing design. It easily withstands workshop dust, cutting fluids, and harsh, humid environments for long-lasting durability.
📏 20-Meter Long-Distance Transmission:Supports standard cable runs up to 20 meters. This allows you to place I/O nodes directly next to field equipment, keeping your main cabinet clean.
⚡ Ultra-Fast Response (<10ms):Captures signals in milliseconds. It perfectly meets the strict demands of high-frequency automated production lines.
🔗 Plug-and-Play Compatibility:Built on the standard IO-Link V1.1 protocol. It seamlessly integrates with major PLC brands like Siemens and Rockwell Automation.

Description

SG-IO-IOL-16DI: 16-Channel Digital Input IO-Link Hub

 

Simplify your control cabinet wiring and reduce installation costs with the SG-IO-IOL-16DI. This compact IO-Link Hub (Class B) brings your sensor signals directly to the field, eliminating the need for long, expensive cable runs back to the PLC.

 

Designed for harsh industrial environments, this module features a rugged IP67-rated housing, making it resistant to dust, moisture, and cutting fluids. Whether you are upgrading an existing line or designing a new automated cell, the SG-IO-IOL-16DI offers the flexibility and reliability you need.

 

Product Feature
 

Standard IO-Link V1.1 Compliance

Acts as a standard IO-Link slave device, ensuring seamless compatibility with all major PLCs and IO-Link masters on the market.

High-Density 16-Channel I/O

Features 8 physical ports, with each port supporting 2 digital I/O signals (NPN or PNP selectable). This maximizes connection density in a single, compact module.

Individual Channel Diagnostics

Every digital input signal can be monitored individually via the IO-Link master, making fault detection and troubleshooting faster and easier.

20-Meter Decentralized Deployment

Supports a maximum communication distance of 20 meters. Its integrated, compact design allows for distributed installation right next to your field sensors, significantly reducing cabinet wiring.

IP67 Industrial-Grade Protection

The fully sealed housing is highly resistant to harsh workshop environments, including cutting fluids, oil contamination, dust, and moisture.

24/7 Continuous Operation

Built for industrial-grade stability, this hub guarantees reliable, uninterrupted performance 24 hours a day, even under high-temperature conditions.

 

Technical features

 

CategoryParameterSG-IO-IOL-16DI-PM8 (PNP)SG-IO-IOL-16DI-NM8 (NPN)
PhysicalDimensions (L x W x H)132 x 30 x 35.2 mm132 x 30 x 35.2 mm
 Housing MaterialABS + PC ShellABS + PC Shell
 Grounding ConnectionNo grounding requiredNo grounding required
 Mounting MethodFixed with two mounting boltsFixed with two mounting bolts
 Weight95 ± 5 g105 ± 5 g
Power SupplyRated Voltage24V DC ± 10%24V DC ± 10%
 Current Consumption17mA (Standby) / 1.6A (Fully Loaded)45mA (Standby) / 1.6A (Fully Loaded)
 Power Supply ModeSensor power supply (US)Sensor power supply (US)
CommunicationProtocolIO-Link V1.1IO-Link V1.1
 InterfaceA-CODE M12 Male, 4-pinA-CODE M12 Male, 4-pin
 Communication RateCOM2 (38.4 kbit/s)COM2 (38.4 kbit/s)
 Max Cable Length20 m20 m
 Minimum Cycle Time3.0 ms3.0 ms
 Process Data Length2-byte input, 0-byte output2-byte input, 0-byte output
I/O PortsNumber of Ports8 independent channels8 independent channels
 Port InterfaceM8 Male, 4-pinM8 Male, 4-pin
 Signal Type16-Channel PNP Digital Input16-Channel NPN Digital Input
 Switching Frequency≤ 250 Hz≤ 250 Hz
 Signal VoltageVH = 11-30V, VL = 0-5VVH = 11-30V, VL = 0-5V
EnvironmentOperating Temperature-25°C to +70°C-25°C to +70°C
 Storage Temperature-40°C to +85°C-40°C to +85°C
 Humidity5% ~ 95% RH (no condensation)5% ~ 95% RH (no condensation)
 Protection RatingIP67 (when bolts are tightened)IP67 (when bolts are tightened)
 Vibration ResistanceGB/T 2423.10-2019 / IEC 60068-2-6:2007GB/T 2423.10-2019 / IEC 60068-2-6:2007
 Surge ImmunityGB/T 17626.5-2019, 2KVGB/T 17626.5-2019, 2KV
CertificationsComplianceCE, RoHS 2.0CE, RoHS 2.0
application

🏭 Typical Applications

🚗 Automotive Assembly
Connect clusters of weld-cell clamps, part-presence photoeyes, and pneumatic valve manifolds directly on robotic end-of-arm tooling (EOAT). The IP67 hub tolerates harsh environments and weld spatter while consolidating dense I/O.
📦 Intralogistics & Conveyor Systems
Manage hundreds of optical sensors and motorized roller drives across vast distribution center lines. These hubs significantly reduce the physical cabling required for long-distance sensor tracking.
⚙️ Packaging Machinery
Simplify the wiring of discrete guard-door interlocks, stack lights, and pneumatic cylinders. Cluster them locally on the machine frame instead of running every single wire back to a main control cabinet.
🔧 Machine Tooling
Consolidate temperature, pressure, and fluid-level switch signals within tight, lubricant-heavy machining enclosures. Keep your control cabinet clean and your field wiring protected.

 

FAQ

 

Q1. What is the difference between the PM8 and NM8 models?

A: The PM8 model supports PNP (positive switching) sensors, which are standard in most European and domestic Chinese machinery. The NM8 model supports NPN (negative switching) sensors, often found in older systems or specific Asian markets. Please check your sensor type before ordering.

Q2. Can I use this hub to control outputs (actuators)?

A: No, the SG-IO-IOL-16DI is an Input-only module (16DI). It is designed to read signals from sensors (like proximity switches or photoelectric sensors). If you need to control valves or relays, please look at our 16DIO (Digital Input/Output) series.

Q3. How far can I place this hub from the IO-Link Master?

A: You can place the hub up to 20 meters away from the IO-Link Master using a standard unshielded 3-wire cable. This allows you to place the I/O directly next to the sensors, saving significant cabling costs back to the main control cabinet.

Q4. Is this module compatible with Siemens or Allen-Bradley PLCs?

A: Yes. Since this hub complies with the standard IO-Link V1.1 protocol, it is vendor-neutral. It works with any PLC that has an IO-Link Master card or module (e.g., Siemens S7-1200/1500, Rockwell Allen-Bradley, Beckhoff, Omron, Mitsubishi).

 

 