Industrial Bus Protocol Controller SG-CG-P4S
SG-CG-P4S
236.90 * 66.42 * 38.24mm
Supports protocols: ProfiNet, EtherCAT, EtherNetIP, and CC-LINK
Description
Features
- Applied to the following protocols: ProfiNet, EtherCAT, EtherNetIP, and CC-LINK
- Can be connected to 4 RFID read/write heads, and control their operations simultaneously
- Configurable automatic reading mode
- Multiple cascaded devices can be connected
- achieve industrial networking direct to PLC digital-controlled system and host computer, etc
- Communication up to 100 meters in length. Connect up to 8 IO devices and meet various application environments with different monitoring requirements
- IP67 protection level, able to adapt to harsh environments such as oil pollution (cutting fluid, etc.), dust, and humidity
- The connections of the power supply, bus, and read-write head are all designed to prevent misconnection, which ensure the reliability of installation and use in industrial sites
- 7 * 24 work time, ensuring industrial grade stability and resistance to high temperatures and harsh environments for continuous operation
- The housing is made of lightweight and sturdy aluminum alloy, with the characteristics of connecting range, strong communication capability, good environmental adaptability, and high protection level
Usage
Automation equipment, machine tools, production lines, industrial communication
Typical applications
★Automation equipment, machine tools
The Industrial Bus Protocol Controller SG-CG-P4S can be applied in machine tools and automation equipment. It can communicate with Sigu RFID reading and writing devices and control up to 16 IO channels for on-site use, facilitating the collection of relevant data and control on-site. The EtherCAT protocol should be used to connect machine tools and automation equipment, to transmit information to the management system for device interconnection, and provide information support for automation control.

★Production lines
Industrial Bus Protocol Controller SG-CG-P4S is maturely applied in production lines such as 3C electronics and automobiles. By connecting with RFID reading and writing devices and other IO devices, it ensures real-time information transmission between the production line site and the control system, assists in achieving mixed flow production, and greatly improves the production efficiency of the production line.
★Engine/component assembly line
The Industrial Bus Protocol Controller SG-CG-P4S can connect RFID reader/writer devices and other IO devices. By identifying RFID tags on components (trays), the processing information is printed and transmitted to the upper computer control system, achieving automated control of part identification, processing process identification, and production cycle control, ensuring the correctness of assembly, and improving assembly efficiency and quality..

Technical features
|
Model and Parameters |
SG-CG-P4S-PN |
SG-CG-P4S-ECT |
SG-CG-P4S-EIP |
SG-CG-P4S-CCL |
SG-CG-P4-EN |
|
|
Picture |
|
|
||||
|
Physical Parameters |
Size |
236.90 * 66.42 * 38.24mm |
236.90 * 66.42 * 38.24mm |
|||
|
Housing Material |
Die cast aluminum alloy |
PBT |
||||
|
Power Supply |
Rated Voltage |
18~30VDC |
||||
|
Rated Current |
IMAX<=0.3A@24V (current of bus module) |
System power supply: IMAX<=0.5A Auxiliary power supply: IMAX<=5A |
||||
|
Power Supply Mode |
Independent dual power supply (system power supply UB, load power supply UL) |
|||||
|
Power Interface |
7/8 hole holder/needle holder, 5 needles |
|||||
|
Power Protection |
with reverse protection and 3000W surge protection |
Equipped with reverse protection and 1500W surge protection, Power supply normal and fault indicator light prompt |
||||
|
Communication |
Communication Protocol |
ProfiNet |
EtherCAT |
EtherNet/IP |
CC-LINK |
Modbus TCP protocol |
|
Network Interface |
Both network ports integrated with switch functionality and comply with the IEE802.3 standard |
Ver 2.0 |
- |
|||
|
System Topology |
Star-topology, tree-r-topology |
Star-topology |
||||
|
Length of Communication Cable |
Max=100m |
Max=50m |
Max=100m |
|||
|
Communication Interface |
D-CODE M12 female head, 4-pin |
A-CODE M12 female/male, 4-pin |
D-CODE |
|||
|
I/O |
I/O Point Count |
4 channels, 2 IO points per channel, adaptive input-output |
4 channels |
|||
|
Switching Quantity |
f <=250Hz, VH=12~24V,VL=0~7V,IOUT<=0.7A |
VH=+16~+24V,VL=0~+10V,Imax<=0.7A |
||||
|
IO Interface |
A-CODE M12 socket, 5-pin |
Each interface has 2 DIO signals |
||||
|
Protection Circuit |
short-circuit protection and fault light prompts available in both input/output channels |
|||||
|
RFID Port |
RFID Connections |
4 independent channels |
||||
|
RFID Interface |
A-CODE M12 female head, 5-pin |
A-CODE inerface |
||||
|
Load Capacity |
VOUT=24V±20%,IOUT<=0.7A |
The read head power supply voltage is the same as the load power supply UL, Maximum load current Imax<=700mA |
||||
|
Circuit Protection |
Power supply anti reverse connection, overvoltage and overcurrent protection |
|||||
|
Fault Diagnosis |
support |
|||||
|
Environmental Adaptability |
Working Temperature |
-40°C~+60°C |
-25°C~+70°C |
|||
|
Storage Temperature |
-40°C~+85°C |
|||||
|
Protection Grade |
IP67 |
|||||
|
Certification |
CE, RoHS 2.0 |
|||||
Dimension (Unit: mM)


Application topology
- 4 readers can be connect to bus module, which provides 8 configurable IO channels
- The communication and power ports of the bus module support cascading or can be used separately

Hot Tags: Industrial Bus Protocol Controller SG-CG-P4S, China Industrial Bus Protocol Controller SG-CG-P4S manufacturers, factory, Bus Protocol Controller, Distributed IO Controller, industrial connectivity products, IO Link hub module, IO Link Master Station