Flexible Force Sensor for Surgical Stapler Force Testing HIT-MSS-H103

Flexible Force Sensor for Surgical Stapler Force Testing HIT-MSS-H103

HIT-MSS-H103 Flexible Sensor
2288 Sensing Points
0 - 400 PSI Range
Ultra-Thin Design
For Stapler QA & R&D

Description

Medical Stapler Clamping Force Sensor | HIT-MSS-H103 Consistent clamping force is critical to the safety and performance of surgical staplers. The HIT-MSS-H103 is a high-resolution flexible pressure sensor designed specifically for the R&D and Quality Assurance testing of these devices.

 

Rather than relying on single-point measurements, this sensor captures a detailed 2D pressure map of the stapler cartridge. It accurately measures force distribution in both firing and non-firing states, helping manufacturers identify uneven pressure points, verify design consistency, and ensure every stapler meets strict medical safety standards before reaching the operating room.

 

Product Feature
 

2,288 Sensing Points

Captures detailed pressure distribution. Spots uneven clamping that single-point sensors miss.

Ultra-Thin & Flexible

Slides between stapler jaws easily. Does not change the gap or affect clamping mechanics.

Up to 400 PSI Range

Covers the force requirements for most surgical stapler models.

Mapping Software Included

Turns raw data into 2D heat maps and reports. Makes R&D and QA analysis faster.

Built for Lab Testing

Handles repeated test cycles. Gives you consistent data every time.

Custom Sizes Available

Fits standard staplers, but we can customize the size and cable for your fixtures.

 

Products Specifications

 

ParameterSpecification
Model NumberHIT-MSS-H103
Sensor TypeFlexible Tactile Pressure Sensor
Sensing Area25.6 mm × 70 mm
Resolution2288 Sensing Points (52 × 44 matrix)
Point Density61.7 points/cm²
Pressure Range0 - 400 PSI
ApplicationMedical Stapler Clamping Force Test
CustomizationSize and Cable Length Available

Testing & QA Applications

 

  • R&D Prototyping: Measures clamping force distribution to verify new stapler designs and optimize jaw mechanics.
  • Production Line QA: Ensures consistent clamping force across manufacturing batches to meet medical safety standards.
  • Field Testing: Portable and flexible enough for on-site verification and troubleshooting at client facilities.

 

FAQ

 

Q: Can this sensor measure the force in real-time during the firing sequence?

A: Yes, the HIT-MSS-H103 has a fast response time suitable for capturing dynamic clamping force changes during the closing and firing process of the stapler.

Q: Is the sensor durable enough for production line testing?

A: The sensor is designed for repeated use in testing environments. However, like all precision measurement tools, its lifespan depends on the specific testing frequency and handling. We can discuss protective overlays if your application involves sharp edges.

Q: Do you provide the software to visualize the pressure data?

A: Yes, our sensor system includes software that converts the raw data into visual pressure maps and numerical reports, making it easy for your engineers to analyze the clamping uniformity.

Q: What is the lead time for a customized size?

A: For standard models like the HIT-MSS-H103, we usually have stock or a short production lead time. Customized sizes typically take 2-3 weeks for prototyping. Please contact us with your specific dimensions.

 

 

Hot Tags: Flexible Force Sensor for Surgical Stapler Force Testing HIT-MSS-H103, China Flexible Force Sensor for Surgical Stapler Force Testing HIT-MSS-H103 manufacturers, factory, flexible force sensor, flexible humidity sensor, flexible magnetic sensor, flexible sensor for environmental monitoring, flexible sensor for gesture recognition, high sensitivity flexible sensor

You Might Also Like

Shopping Bags